• GE Druck UPS-II Loop Calibrator*DIHENTIKAN LIHAT DRUCK UPS III*

GE Druck UPS-II Loop Calibrator*DIHENTIKAN LIHAT DRUCK UPS III*

Not yet rated Tulis ulasan
Rp.21.250.000
Ketersediaan:
DIHENTIKAN
Kode Produk:
UPS-II
Merk:
GE Measurement & Control

  • Free delivery

  • Money back guarantee

Share

The GE Druck UPS-II Smart Loop Calibrator for Milliamps is a day-to-day test and calibration tool that is tough, reliable, accurate and easy to use. It can supply power (source mode) and produce readings (measure mode) to perform field calibrations on 2-wire devices. Output currents are adjustable to a resolution of 10 microamps in both source and transmitter simulation modes.

Fixed Steps
The GE Druck UPS-II loop calibrator can source or stimulate fixed calibration currents to test or calibrate receivers and to stroke valves. Different current levels are available from the menu.
4-20mA Linear: 4 - 8 - 12 - 16 - 20mA
0-20mA Linear: 0 - 5 - 10 - 15 - 20mA
4-20mA sq.rt (Flow): 4 - 5 - 8 - 13 - 20mA
0-20mA sq.rt: 0 - 1.25 - 5 - 11.25 - 20mA
4-20mA: 3.8 - 4 - 4.2 - 12 - 19 - 20 - 21mA

The GE Druck UPS-II loop calibrator's output currents can be changed manually or automatically. The time between steps is 10 seconds in the auto-stepping mode. In the valve mode, auto-stepping will be 3.8 - 4 – 4.2 or 19 - 20 - 21mA.

Ramping
The GE Druck UPS-II loop calibrator can source or simulate with high resolution a continuous up / down cycle between 4 and 20mA or 0 and 20mA. The travel time between limits is 60 seconds.

Reading in Percentage
The GE Druck UPS-II loop calibrator can display readings in percentage of a 4-20mA or 0-20mA span and can also read or simulate dP-transmitters directly in percentage of flow.

The standard instrument kit provided with the GE Druck UPS-II loop calibrator includes carrying case, alkaline batteries, set of test leads, users guide, and calibration certificate.

An intrinsically safe version of the GE Druck UPS-II loop calibrator is available.


Features:
  • Optimised for use in the field – powers (24V DC) and reads 2-wire transmitters for field calibrations
  • Sources and reads milliamps with output current from 0 to 21.00mA and resolution of 10microamps
  • Reads and simulates DP transmitters in % of flow
  • Auto-ramp cycling for endurance testing
  • Auto-stepping procedures – ideal for hands-free calibration
  • Fixed calibration currents
  • Fixed currents for valve stroking

What's In The Box:
  • (1) GE Druck UPS-II Smart mA Loop Calibrator
  • (1) Carrying Case
  • (1) Set of Batteries
  • (1) Instruction Guide
  • (1) Spare Fuse

Brochure/Datasheet
Instruction manual


Catatan: Harga tidak mengikat, sewaktu waktu bisa berubah tanpa pemberitahuan dahulu

Tulis ulasan